Configuration 27
HIT-4U HP-327
FLOW MENU
Menu
Item
Description Options Min
Max
Value
Default
TURBIN Turbine serial #
Numeric
Entry
0000000
9999999
1234567
K FACT K Factor Method
Average
Table
N/A Average
KFAC D
The number of decimal
places for the K-Factor.
For Average K and K
Factors in table.
0
0.0
0.00
0.000
N/A 0.000
AVG K Average K Factor
Numeric
Entry
0.001
9999999.9
1.000
C FACT
Flow and total
multiplier
Numeric
Entry
0.001
99999.999
1.000
UNITS
Units of measure for
flow.
LB, KG, SCF,
SCFx1000, and NM3
have K-Factors
adjusted at fixed
temperature and
pressure
Gallons
Barrels
Liters
LB
KG
ACF
ACFx1000
SCF
SCFx1000
M3
NM3
N/A Gallons
TOTL D Total Decimal Point
0
0.0
0.00
0.000
N/A 0.0
RATE Time base for flow rate.
/sec
/min
/hour
/day
N/A /sec
RATE D Rate Decimal Point
0
0.0
0.00
0.000
N/A 0.0
CUTOFF
Low flow frequency
cutoff threshold in Hz.
Numeric
Entry
0.000
100.000
0.000