2 8 C o n f i g u r a t i o n
HP-327 HIT-4U
TABLE MENU
Menu
Item
Description Options Min
Max
Value
Default
RECAL
Restores K-Factor
table to factory
default values to
allow entry of new
calibration data.
NO
YES
N/A NO
POINTS
Number of points 2-20 2
20
10
FR 01
Frequency points
2 – 20. Follow
monotonic and
separation rules.
Numeric
Entry
0.001
5000.000
Fr20 =
5000.000
Fr19=
4999.999
Fr18
=49999.998
ETC.
K 01
K factor points 2 -
20
Numeric
Entry
0.001
9999999.9
1.000
MODBUS MENU
Menu Item
Description Options Min
Max
Value
Default
ADDRSS
Modbus address Numeric
entry
000-254
BAUD
Baud rate for
RS485
*9600
57600
115200
N/A 9600
*Currently fixed at 9600.
Flow-Tech, Inc. | In MD 410-666-3200 - In VA 804-752-3450 | www.flowtechonline.com