9
After adjusting the belt tension, lock the motor
fastening nuts
10
If possible, check the belt tension with suitable
instruments
1
1
In service conditions, the belt tension is between 380 and 400 Hz
When installing a new belt, overtension it up to 450 Hz to recover the natural belt elongation that
occurs in the first 48 hours