Furnace
Operating Instructions
Set thermostat FAN control
to AUTO and either HI or
LOW settings.
Set thermostat control 10
o
higher than motor home air
temperature, control is locat-
ed at right side of thermostat.
Set SYSTEM control to
HEAT.
Allow 40 to 60 seconds for
furnace to begin operating.
Set temperature to desired
setting.
If furnace does not light, and you do not smell gas, repeat the above procedure.
If furnace does not ignite after three attempts slide thermostat control to OFF and
call a qualified service technician or your gas supplier.
To shut down furnace slide thermostat control to OFF. After you have turned the
furnace off or burner has shut down the fan will run for approximately 30 to 60
seconds to cool down the furnace.
Cleaning Furnace
Clean entire furnace and air tube passageways periodically to remove dust, lint,
etc. Check gas systems for leaks at least once a year. Check and clean blower wheel
annually. Control compartment of furnace must be kept clean; failure to do so could
result in operational or fire hazards.
Before each heating season starts furnace should be thoroughly cleaned of wasp
and spider nests, lint accumulations and other debris. Debris will restrict air flow for
combustion, bind up combustion air impeller and keep blower fan from running. Check
burner pilot orifices for debris. Lint accumulations will cause blower to become unbal-
anced and vibrate, restrict ability of blower to move air, and if blown onto heat exchang-
er will cause odor and fire hazard. Contact your authorized dealer service technician for
annual cleaning.