Operation
Detector only indicates presence
of Propane Gas at sensor. Propane Gas
may be present in other areas. This
devise is intended for detection of
Propane Gas leaks only. LP gas detec-
tor is operating at all times when it is
connected to its power source. This
detector is a safety device, and must
not be connected in such a way as to
allow it to be switched off or become
disconnected from its power supply.
When the motor home is equipped with a master cutoff switch, the detector will be turned
off when the switch is turned OFF. When the detector is powered or turned ON a green
indicator light will be lit. After 3 minutes the detector will begin monitoring immediate
environment for combustible vapors. Propane you use to cook, refrigerate, and eat with
is combustible. Should a leak occur, when gas reaches the detector in sufficient con-
centrations, your detector will produce a pulsating alarm sound and A RED indicator
alarm light will flash. This alarm (4 rapid beeps per second) will continue to sound until
gas has dissipated or until reset button is pressed. The reset button only stops alarm
from sounding for 60 seconds.
Gas detector is powered by your motor home battery and/or your converter. It
draws less current than drawn by one instrument panel lamp. Your detector will oper-
ate to detect gas until your battery is drained down to 9 volts. (Your low battery condi-
tion 10.4 volts). If the power source (battery and/or converter) is disconnected, or if
power is otherwise interrupted, detector will not operate.
The gas detector has a self check circuit which runs at all times while the detector
is powered. In the event that circuitry fails, a fault alarm will sound and the fault indic-
Admiral 5-5
LP
LP
Gas Systems
Gas Systems
HOLIDAY RAMBLER
2000
! WARNING !
When alarm sounds open all doors and windows to air out motor home and
turn gas off at LP tank. Do not re-enter motor home until alarm stops sounding.
If alarm sounds a second time after gas is turned back on, leave gas off and con-
tact a qualified service technician to find source and repair gas leak.