Professional Install Guide
System Types
Compatible with 24-volt systems such as forced air, hydronic, heat pump (including dual fuel),
oil, gas and electric.
Does not work with electric baseboard heat (120/240V).
Must be installed by a trained, experienced technician
Read these instructions carefully. Failure to follow these instructions can
damage the product or cause a hazardous condition.
Mercury Notice:
If this product is replacing a control that contains mercury in a sealed tube, do not place the
old control in the trash. Contact the Thermostat Recycling Corporation at 18002388192 or
thermostat-recycle.org for information on how and where to properly and safely dispose an old
thermostat.
Disconnect power before installation.
Can cause electrical shock or equipment damage.
Round™ Smart Thermostat
TH8732WFH5004
72
Search for local rebates:
HoneywellHome.com/Rebates
Installation
1 Set Jumper Switches
R Jumper Switch:
For single
transformer
systems, move
switch up.
For dual
transformer
systems, move
switch down.
Jumper Switch for humidifier, dehumidifier, or ventilation:
For single wire
products, set
the switch to 1
Wire.
For two wire
products,
set the switch to
2 Wire.
2 Wiring: Terminal Designations
L Heat pump system monitor K Optional C-wire adaptor
C Common wire from secondary
side of cooling transformer, if 2
transformers
G Fan relay
W2
(AUX)
2nd stage heat relay (heat pump
auxiliary, emergency heat)
Y2 2nd stage compressor
contactor
W
(O/B)
1st stage heat relay (changeover
valve for heat pumps)
Y 1st stage compressor
contactor
U1 Terminal for indoor air quality
products (humidifier, dehumidifier,
ventilator)
R Heating power. Connect to
secondary side of heating
system transformer
U2 Terminal for indoor air quality
products (humidifier, dehumidifier,
ventilator)
Rc Cooling power. Connect to
secondary side of cooling
system transformer
3 Connect wires and mount wallplate
Connect wires and mount the wall
plate using screws and anchors
provided.
Note: The illustration to the right
shows the most common wiring.
REQUIRED: A CWire (common wire)
is needed for 24 VAC power.
Electrical Ratings:
Terminal Voltage (50/60 Hz) Max. Current Rating
W - O/B (Heating) 18 to 30 VAC 1.00 A
W2 - Aux/E (Heating) 18 to 30 VAC 0.60 A
Y (Cooling) 18 to 30 VAC 1.00 A
Y2 (Cooling) 18 to 30 VAC 0.60 A
K 18 to 30 VAC 1.00 A
G (Fan) 18 to 30 VAC 0.50 A
L (Output) 18 to 30 VAC 1.00 A
U1, U2 18 to 30 VAC 0.40 A
4 Firmly snap the thermostat into
place
The thermostat will glow and
display the screen for up to three
minutes while it starts up.
72
Question and Answer IconNeed help?

Do you have a question about the Honeywell Home Round TH8732WFH5004 and is the answer not in the manual?

Honeywell Home Round TH8732WFH5004 Specifications

General IconGeneral
BrandHoneywell Home
ModelRound TH8732WFH5004
CategoryThermostat
LanguageEnglish

Summary

Installation

System Types

Compatible with 24-volt systems; excludes electric baseboard heat.

Set Jumper Switches

Configure jumper switches for system type and accessories like humidifiers.

Wiring Terminal Designations

Details of thermostat wire terminal functions for system connections.

Connect Wires and Mount Wallplate

Instructions for wiring connections and mounting the wallplate securely.

Firmly Snap Thermostat into Place

Guidance on physically attaching the thermostat to the wallplate.

Setup: On-screen menus

Access Main Menu

Press and hold the Weather button for 5 seconds to access the Main Menu.

Device Details and Password

Navigate to Device Details to find the 4-digit password (date code).

Navigate Setup Options

Highlight and select Set Up, then Contractor, then Set Up again.

Enter System Password

Input the four-digit password using the navigation and OK buttons.

Configure Settings

Step through and adjust various settings using navigation and OK.

Save Configuration Changes

Choose to save changes (Yes) or exit without saving (No).

Setup Options

Temperature Setpoints

Configure minimum and maximum setpoints for heating and cooling.

Heating System Configuration

Define heating system type, equipment type, and backup heat settings.

Ventilation and Dehumidification

Configure settings for ventilation types, humidifiers, and dehumidifiers.

Advanced Staging and Recovery

Adjust backup heat staging, lockout points, and adaptive recovery settings.

Cycle Rates and Temperature Offsets

Set cycles per hour, temperature display offset, and humidity offset.

Basic Operations

Thermostat Interface Overview

Visual guide to thermostat controls: temperature, cooling, heating, and Home/Away.

Weather Information

View current weather and 6- and 12-hour forecasts on the thermostat.

Related product manuals