The T6RWP Smart Thermostat wireless thermostat comes unbound from the factory and binding is required during
installation (see previous page).
The binding operation described below is only required if:
The T6RWP thermostat or Receiver box is replaced.
The T6RWP thermostat or Receiver box has incorrect or no binding data stored.
- Thermostat will indicate the Alert message: NO RECEIVER BOX BINDING
- Receiver box status LED remains green blinking (no communication from thermostat)
- Receiver box status LED does not light up (not bound).
1. Put the Receiver box into binding mode by pressing the Heat button for 3 sec.
- The first LED will flash amber
2. Enable binding on the thermostat:
- Enter the advanced menu by pressing the button for 5 sec.
- Navigate to BINDING
- Select BIND and the signal will be sent
3. When binding is successful:
- Thermostat will show SUCCESS
- First Receiver box status LED will show green
Note: When the Receiver box has been bound before first press with a small pin
the pinhole for approximately 3 seconds to reset the binding. All LED’s will
flash amber for a moment.
When binding is NOT successful:
- Thermostat will show FAILED
- Receiver box will exit binding after 3 min.
RF communication might be too far or is blocked due to wrong location of the
Thermostat or Receiver box. Try to move closer or re-locate and re-bind again.
After power up, SETUP is displayed on the thermostat’s screen.
Set clock format, time
and date.
to setup using the
Honeywell Home App is
currently unsupported)