10 Report Code
1st 01 2nd 00 10
Enter the report code for this zone, which consists of 2 hexadecimal digits, each in turn
consisting of 2 numerical digits. For example, for a report code of “10,” enter 01 and 00.
For Contact ID
®
, entering any non-zero entry as the first digit enables the report code for
this zone. Refer to the System Communication section for information about report codes
and formats.
Report code digits: 1-9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F
00 to disable; [] to continue
02 HARDWIRE TYPE
EOL 0
This prompt appears only for zone numbers 01-06.
Enter the desired hardwire type:
0 = EOL; 1 = NC; 2 = NO
[] to continue
02 Response Time
1
This prompt appears only for hard-wired zones 01-06 (zone 02 is used as an example in
display).
Enter the desired response time for this zone:
0 = 10mSec; 1 = 350mSec; 2 = 700mSec; 3 = 1.2 seconds
[] to continue
10 INPUT TYPE
RF TRANS 3
For wired zones 1-6, the Input Type automatically displays as HW and cannot be edited.
All of the RF transmitters have one or more unique factory-assigned input loops (ID codes).
Each of the input loops requires its own programming zone (e.g., a 5804's four button inputs
require four programming zones). Select the desired input type for the transmitter zone
being programmed.
3 = RF (supervised RF transmitter; sends fault, restore, and low-battery signals, and sends
periodic check-in signals; transmitter must stay within receiver's range)
4 = UR (unsupervised RF transmitter; sends fault, restore, and low-battery signals, but
does not send periodic check-in signals; transmitter may be carried off-premises)
5 = BR (unsupervised button type RF transmitter; sends fault and low battery signals when
activated, does not send restore or check-in signals; transmitter may be carried off-
premises)
[] to continue
10 INPUT S/N: L
A022-4064 1
For wireless transmitters, enroll the serial number and loop number.
1. a. Transmit two open/close sequences. If using a button-type transmitter, press and
release the button twice, but wait about 4 seconds before pressing the button the
second time.
OR
b. Manually enter the 7-digit serial number printed on the label of the transmitter.
Press the [] key to move to the “L” position, then enter the loop number (see Loop
Identification chart on back cover).
If desired, you can press the [C] key to copy the previously enrolled serial number
(used when programming a transmitter with several input loops). The cursor moves to
the loop number position.
c. To delete an existing serial number, enter 0 in the loop number field. The serial
number will change to 0's. If 0 was entered in error, simply re-enter the loop number or
press [#], and the serial number will return to the display.
2. Press [] to continue. The system now checks for a duplicate serial/loop number
combination.
10 INPUT S/N L
A022-4064 1
If the serial/loop number combination is not a duplicate in the system, a display showing the
serial number and loop number entry appears.
[] to continue
XMIT TO CONFIRM
PRESS TO SKIP
This prompt will only appear if you answered “Yes” at the “SET TO CONFIRM” prompt.
The system now enters a confirmation mode so that the operation of the actual programmed
input can be confirmed.
Activate the loop input or button that corresponds to this zone.
[] to continue