AreaRAE Plus & AreaRAE Pro User’s Guide
112
CAUTION!
TheAreaRAE, PGM-65XX, shall only be charged using a charger specifically supplied for use with the
unit with a maximum output voltage of 17V.
Use of non-RAE Systems components will void the warranty and can compromise the safe performance
of this product.
PGM-65XX Marking
The PGM-65XX is certified according to the IECEx scheme, ATEX and CSA for US and Canada under
the non-sparking safety method of protection.
The PGM-65XX is marked with the following information:
RAE SYSTEMS
3775 N. 1
st
. St., San Jose
CA 95134, USA
Type PGM-65XX.
Serial No/barcode: XXXX-XXXX-XX
IECEx XXX15.XXXX
Ex ic nA [ic] IIC T4 Gc
XXX 15 ATEX XXXX
II 3G Ex ic nA [ic] IIC T4 Gc
Cl.I Dv 2, Grps A,B,C,D
T-Code T4.
C22.2 No.152-M1984
ANSI/ISA-12.13.01-2013
-20º C < Tamb < +50º C;
Um:17V
RAEMet connection:Uo: 5.2V, Po: 0.788W, Lo:198μH, Co:1000μF
SSRelay connection: Ui: 24V, Ii:250mA
Battery pack: W01-3007-000
CAUTION: READ AND UNDERSTAND INSTRUCTION MANUAL BEFORE OPERATING OR
SERVICING
ATTENTION: LIRE ET COMPRENDRE MANUEL D’INSTRUCTIONS AVANT D’UTILISER OU
SERVICE
Operation Area and Conditions
Hazardous Areas Classified by Zones
PGM-65XX are intended to be used in hazardous areas classified zone 2 within the temperature range of
-2C to +5C, where gases of explosion groups IIA, IIB or IIC and T4 may be present.
Hazardous Areas classified by Divisions
PGM-65XX is intended to be used in hazardous areas classified for Class I Div. 2, within the
temperature range of -20º C to +50º C, where gases of explosion groups A, B, C or D and temperature
code T4 may be present.