TBL TBL T T NO EOLCV-NC V+
132
TEST
50%
100%
75%
25%
Select the mounting location.
Wire the unit.
Mount the unit.
a Walk-test the sensor.
Mounting Location Guidelines
2.3 m (7’6”) mounting height
Avoid direct or reflected sunlight
Aim sensor away from windows or heating/
cooling devices
Sensor must have a clear line-of-sight to
protected area
Use a small screwdriver to unfasten the housing
latch. Gently pull apart the housings.
Push outward on the PCB latch and lift the PCB
out of the housing.
Slide the wire through the wire channel in the
back housing.
Mount the back housing flat against a wall or in a
corner.
Replace the PCB.
Connect wires as shown using 0.3 - 1.0 mm
2
(18 to 22 gauge) wire size. Observe proper
polarity.
Use Switch 3 to select the appropriate fluorescent
light filter (see Dip Switch Settings chart on the next
page).
Apply power to the unit. Initialization is complete
when the LED stops flashing slowly.
Adjust the microwave range to minimum setting
(25%) by turning the range adjustment counterclock-
wise using a small screwdriver.
Replace the front housing.
Begin walking through the detection area.
- The LED will turn red, indicating an alarm detection.
Increase the microwave range as necessary.
Repeat the items in step 5a until proper detection
range is obtained.
b Optional: Walk-test using Zone Finder
Corner
Mount
Wire Channel
Wall Mount
75%
100%25%
50%
DT-7450/7450C DUAL TEC
®
Motion Sensor Installation Instructions
Use the Zone Finder mode to identify the PIR and/or
microwave pattern. In Zone Finder mode the red
LED is disabled.
Separate the sensor housings and
remove the printed circuit board (PCB).
V+V-
NC
C
Alarm
125 mA
25 VDC
Power
35 mA
7.5-16 VDC
(For UL 8.0-16 VDC)
NO
T
T
Tamper
50 mA
24 VDC
EOL
DT-7450
DT-7450C
Apply a screwdriver for five seconds to short the
test pads.
During the Zone Finder walk-test mode, the LED
turns:
- green for one second for every PIR detection;
- yellow for two seconds for every microwave
detection.
Adjust the microwave range as necessary.
Zone finder mode times out after ten minutes.