INSTALL GUIDE
33-00135EFS-07
Home
ERM5220R
Equipment Remote Module
WITH REDLINK™ WIRELESS TECHNOLOGY
Table of Contents
About the ERM5220R 2
Installation Checklist 3
Terminal Designations 4
Installation 6
Checkout 12
Troubleshooting 13
Specifications 15
5 Year Warranty 17
CAUTION
Read these installation instructions completely and follow them
carefully.
Installation must be performed by a qualified service technician
and must comply with local codes.
Disconnect power to all relevant devices before installing or
servicing the ERM.
Failure to connect the device according to these instructions may
result in damage to the device, the controls, and/or personal injury.
33-00135EFS_D.book Page 1 Friday, September 8, 2017 1:59 PM

Questions and Answers

  • M
    Michael BruceAug 15, 2025
    What to do if the compressor doesn’t turn on and “Y” LED is blinking on my Honeywell ERM5220R Remote Control?
    • H
      Heather RodriguezAug 15, 2025
      If the compressor on your Honeywell Remote Control isn’t turning on and the “Y” LED is blinking, it's likely due to a 5-minute compressor lockout after a power cycle. Please wait 5 minutes; the compressor will automatically turn on after this safety timeout.
  • M
    mariolynnAug 18, 2025
    Why is the connected LED on my Honeywell ERM5220R Remote Control red?
    • U
      ugardnerAug 18, 2025
      If the connected LED on your Honeywell Remote Control is red, it indicates a loss of communication with the system. Verify that the thermostat and/or Equipment Interface Module are powered and functioning correctly.
  • H
    hmorganAug 21, 2025
    How to fix no LEDs on my Honeywell ERM5220R?
    • M
      markdayAug 22, 2025
      If no LEDs are illuminated on your Honeywell Remote Control, it indicates that there is no power to the device. Verify that there is 24 VAC at the R/C terminals.
  • J
    James GarrettAug 26, 2025
    How to troubleshoot Honeywell ERM5220R relays not switching as expected?
    • D
      David CarpenterAug 26, 2025
      If the relays on your Honeywell Remote Control aren’t switching as expected, it may be due to an incorrect jumper configuration. Check the jumper configuration. If it is incorrect, unenroll from the system, change the jumper, and then re-enroll with the system.
  • S
    spatelAug 29, 2025
    Why is the outdoor temperature reading too high on my Honeywell ERM5220R Remote Control thermostat?
    • M
      Matthew ChambersAug 29, 2025
      If the outdoor temperature reading at the thermostat for your Honeywell Remote Control is too high, it's likely due to sun exposure on the sensor. Ensure the outdoor temperature sensor isn't in direct sunlight. You may need to use a longer wire to mount it in an ideal, shaded location.
  • B
    Briana SimsSep 1, 2025
    What to do if my Honeywell ERM5220R thermostat shows “—” for outdoor temperature?
    • R
      robertskevinSep 1, 2025
      If your Honeywell Remote Control thermostat displays “—” for the outdoor temperature, it indicates that the wired outdoor temperature sensor has failed. Check the sensor for a short circuit or an open circuit.
  • D
    Douglas CollinsSep 4, 2025
    Why is the connected LED off on my Honeywell ERM5220R Remote Control?
    • M
      Mindy VegaSep 4, 2025
      If the connected LED on your Honeywell Remote Control is off, it indicates that the device is not enrolled with the system. Enroll the device with the system.
  • M
    Mrs. Crystal YoungSep 8, 2025
    Why is no outdoor temperature shown on my Honeywell ERM5220R Remote Control thermostat?
    • P
      Pam ArellanoSep 8, 2025
      If no outdoor temperature is shown on the thermostat for your Honeywell Remote Control, it could be because there is no wired outdoor temperature sensor connected to the ERM, or the device is configured as a boiler. Connect the outdoor temperature sensor to the S1/S1 terminals. Note that the device only reports outdoor temperature when configured as a compressor.
  • J
    Jonathan Bailey DVMSep 12, 2025
    Why doesn’t the emergency backup control function on my Honeywell Remote Control?
    • T
      Todd MendozaSep 12, 2025
      If the emergency backup control isn’t functioning on your Honeywell Remote Control (when configured as a boiler), it indicates that there is no valid indoor temperature sensor. Check the sensor for a short circuit or open circuit, or install an indoor temperature sensor on the S1/S1 terminals.

Summary

About the ERM5220 R

Installation Checklist

Terminal Designations

Compressor Terminal Designations

Details terminal functions for compressor systems, including sensor and control connections.

Boiler Terminal Designations

Outlines terminal functions for boiler systems, including sensor and freeze protection uses.

INSTALLATION

Wiring the ERM

Step-by-step guide for preparing the cable and connecting wires to the ERM unit.

Thermostat Pairing

Instructions for pairing the ERM with a compatible RedLINK thermostat for system integration.

Mounting ERM

ERM Mounting Instructions

Guidance on selecting a suitable exterior wall location and proper orientation for the ERM.

Checkout

TROUBLESHOOTING

Reset Procedure

Steps to reset the ERM unit by holding the Connect button for 10 seconds.

SPECIFICATIONS

SEPARABLE PARTS

REGULATORY INFORMATION

FCC Regulations

Device compliance with Part 15 of FCC Rules, subject to two conditions.

IC Regulations

Device compliance with Industry Canada's licence-exempt RSSs, subject to two conditions.

FCC Warning

User warning regarding modifications not approved by the party responsible for compliance.

5 YEAR WARRANTY

Honeywell ERM5220R Specifications

General IconGeneral
BrandHoneywell
ModelERM5220R
CategoryRemote Control