INSTALL GUIDE
33-00135EFS-05
ERM5220R
Equipment Remote Module
WITH REDLINK™ WIRELESS TECHNOLOGY
Table of Contents
About the ERM5220R 2
Installation Checklist 3
Terminal Designations 4
Installation 6
Checkout 12
Troubleshooting 14
Specifications 16
5 Year Warranty 18
CAUTION
Read these installation instructions completely and follow them
carefully.
Installation must be performed by a qualified service technician and
must comply with local codes.
Disconnect power to all relevant devices before installing or
servicing the ERM.
Failure to connect the device according to these instructions may
result in damage to the device, the controls, and/or personal injury.
33-00135EFS_C.book Page 1 Monday, May 2, 2016 1:52 PM

Questions and Answers

  • J
    Jacqueline VillegasAug 14, 2025
    Why doesn't my Honeywell Control Unit compressor turn on, and the “Y” LED is blinking?
    • B
      Bradley ThomasAug 15, 2025
      The compressor might not be turning on, and the “Y” LED might be blinking due to a 5-minute compressor lockout that occurs after a power cycle. Wait 5 minutes, and the compressor will turn on after the safety timeout.
  • R
    Robert WebbAug 18, 2025
    What to do if the Honeywell Control Unit thermostat shows “—” for outdoor temperature?
    • H
      hamiltonbethAug 18, 2025
      If the thermostat displays “—” for the outdoor temperature, it indicates that the wired outdoor temperature sensor has failed. Check the sensor for a short circuit or an open circuit.
  • T
    Timothy ClarkAug 21, 2025
    Why is the outdoor temperature reading at the Honeywell Control Unit thermostat too high?
    • A
      Angela DennisAug 21, 2025
      An outdoor temperature reading at the thermostat that is too high is usually caused by sun load on the sensor. Make sure the outdoor temperature sensor is not in direct sunlight. You may need to use a longer wire to mount it in an ideal location.
  • L
    Linda WangAug 25, 2025
    How to fix relays that don’t switch as expected on a Honeywell Control Unit?
    • A
      Amy HillAug 26, 2025
      If the relays aren’t switching as expected, the cause may be incorrect jumper configuration. Check the jumper configuration. If it is incorrect, unenroll from the system, change the jumper, and then re-enroll with the system.
  • W
    William WatkinsAug 28, 2025
    What to do if the connected LED on my Honeywell Control Unit is red?
    • D
      David BellAug 28, 2025
      If the connected LED is red, it indicates a loss of communication with the system. Verify that the thermostat and/or Equipment Interface Module are powered and functioning correctly.
  • M
    Mrs. Ashley ClarkAug 31, 2025
    Why is there no outdoor temperature shown on my Honeywell Control Unit thermostat?
    • C
      cfloresAug 31, 2025
      If there is no outdoor temperature shown on the thermostat, it may be because there is no wired outdoor temperature sensor connected to the ERM, or the device is configured as a boiler. Connect an outdoor temperature sensor to the S1/S1 terminals. Note that the device only reports outdoor temperature when configured as a compressor.
  • J
    Jessica HolmesSep 3, 2025
    What to do if the emergency backup control doesn’t function on my Honeywell Control Unit (if configured as boiler)?
    • K
      Kimberly CrawfordSep 4, 2025
      If the emergency backup control doesn’t function (when configured as a boiler), the cause may be that there is no valid indoor temperature sensor. Check the sensor for a short circuit or open circuit, or install an indoor temperature sensor on the S1/S1 terminals.
  • S
    Stacy SandovalSep 7, 2025
    What to do if no LEDs are on on my Honeywell Control Unit?
    • J
      James GrahamSep 7, 2025
      If no LEDs are on, it means there is no power to the device. Verify 24 VAC at the R/C terminals.
  • D
    Debra SheppardSep 12, 2025
    What to do if the connected LED is off on my Honeywell Control Unit?
    • G
      greerjamieSep 12, 2025
      If the connected LED is off, the device is not enrolled with the system. Enroll the device with the system.

Summary

About the ERM5220 R

Installation Checklist

Terminal Designations for Compressor

Terminal Designations for Boiler

Installation Wiring

Mounting ERM

Checkout

Troubleshooting

Reset Procedure

Procedure to reset the ERM by holding the connect button for 10 seconds.

Specifications

Separable Parts

FCC Regulations

IC Regulations

5 Year Warranty

Honeywell ERM5220R1018 Specifications

General IconGeneral
BrandHoneywell
ModelERM5220R1018
CategoryControl Unit
LanguageEnglish

Related product manuals