L-Series, Indoor Strobes and Horn Strobes
Technical Specifications
9021-60928 | C | 03/18
©2018 Honeywell International Inc.
For a complete listing of all
compliance approvals and
certifications, please visit:
http://www.gamewell-
fci.com/en-US/
documentation/Pages/
Listings.aspx
E3 Series® and Gamewell-FCI®
are registered trademarks of
Honeywell International Inc.
UL® is a registered trademark
of Underwriters Laboratories
Inc.
This document is not intended
to be used for installation
purposes. We try to keep our
product information up-to-
date and accurate. We cannot
cover all specific applications
or anticipate all requirements.
All specifications are subject to
change without notice.
Honeywell Gamewell-FCI
12 Clintonville Road
Northford, CT 06472-1610
203.484.7161
www.honeywell.com
For more information
Learn more about Gamewell-FCI’s L-Series, Indoor Strobes and
Horn Strobes and other products available by visiting
www.Gamewell-FCI.com
SYSTEMS
Temperature Ranges:
Standard Operating Temperature:
32°F to 120°F (0°C
to 49°C)
Humidity Range:
10 to 93% non-condensing
Voltages:
Strobe Flash Rate:
1 flash per second
Nominal Voltage:
Regulated 12 VDC or regulated 24
DC/FWR
1
Operating Voltage Range
2
:
8 to 17.5 V (12 V nominal)
or 16 to 33 V (24 V nominal)
Operating Voltage Range (MDL3):
8.5 to 17.5V(12 V
nominal)
or
16.5 to 33 V(24V nominal)
Wire Gage:
Input Terminal Wire Gauge:
12 to 18 AWG
Dimensions:
Ceiling-Mount Dimensions (including lens):
6.8"
diameter × 2.5" high (173 mm diameter × 64 mm high)
Ceiling-Mount Surface Mount Back Box Skirt
Dimensions (SBBCR, SBBCW):
6.9" diameter x 3.4"
high (175 mm diameter x 86 mm high)
Notes:
1. Full Wave Rectified (FWR) voltage is a non-
regulated, time-varying power source that is
used on some power supply and panel outputs.
2. P, S, PC, and SC products will operate at 12 V
nominal only for 15 and 30 cd.
TEMPERATURE AND HUMIDITY RANGES
This system meets NFPA requirements for operation at 0
– 49°C/32 – 120°F and at a relative humidity 93% ± 2%
RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F).
However, the useful life of the system's standby batteries
and the electronic components may be adversely affected
by extreme temperature ranges and humidity. Therefore,
it is recommended that this system and its peripherals be
installed in an environment with a normal room
temperature of 15 – 27°C/60 – 80°F.
STANDARDS
The L-Series, Ceiling Strobes and Horn Strobes are
designed to comply with the following standard:
UL Standard:
UL 1971 and UL 464
AGENCY LISTINGS AND APPROVALS
These listings and approvals apply to the modules
specified in this document. In some cases, certain
modules or applications may not be listed by certain
approval agencies, or listing may be in process.
Consult factory for latest listing status.
UL:
S5512, S4011
CSFM:
7135-1653:0503
7125-1653:0504
ISO 9001 Certification

Related product manuals