EasyManua.ls Logo

Honeywell GSMX - Primary Account Information; Remote Access Setup

Honeywell GSMX
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GSMX Installation and Setup Guide
– 16 –
PROMPTS ENTRY OPTIONS DESCRIPTION
NOTE: Account information is provided by the central station administrator.
12
Primary City
ID
(??)_
[01-99]
Enter the 2-digit primary city ID,
01-99 (decimal).
13
Primary CS
ID
(??)
[01-FE] Enter the 2-digit primary central
station ID number, 01-FE (HEX).
14
Primary Sub
ID
(????)
[0001-
9999]
Enter the 4-digit subscriber
account number, 0001-9999
(decimal).
15
Device
Address
(03)_
[01-30]
The module communicates with
the panel as a Long Range Radio
(LRR) device. Enter ECP device
address.
NOTE: When programming the
control, enable the LRR output.
Setting up the Remote Access Feature
Remote Access enables the user to control the security system using a web browser.
This feature must be configured at the AlarmNet Direct website
as follows:
Remote Access must be enabled by selecting "Enabled" at the Remote Access
prompt.
A keypad address must be enabled in the GSMX in order for the module to
communicate with the control panel.
At the “Keypad Type” prompt, select the appropriate Keypad.
16
Remote
Access
Y/N
(N)_
[Y], [N] Press [Y] to allow the end user to
access their system via a website.
Availability of this service is
controlled by the dealer via the
web-based programming tool on
the AlarmNet Direct website.
17
Keypad
Address
(28)_
[01-30]
NOTE: This prompt will only
appear if the Remote Access
feature has been enabled.
Must be programmed if using the
Remote Access feature. Enter the
appropriate device address.

Related product manuals