98 | Performance Series Full PoE Network Video Recorder User Guide
6. If you want to save your settings and exit the SETTING menu, click OK..
Configuring Automatic Registration Settings
Automatic Registration allows the device to automatically register to the proxy you have
specified. This allows you to use the client-end to access the NVR through the proxy, where the
proxy has a switch function. In the network service, the device supports the server address of
the IPv4.
To configure the automatic registration settings
1. Configure the proxy server address, port, and sub-device name at the device end.
Note The proxy server generates a serial number for the sub-device ID.
2. Enable the auto register function in the NVR.
The NVR should now be able to automatically register to the proxy server.
Configuring Alarm Center Settings
To configure the alarm center
1. In the SETTING field in the Main Menu, go to NETWORK > Alarm Center.