EasyManuals Logo

Honeywell HW4000 User Manual

Honeywell HW4000
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Air Filter Maintenance
22 www.honeywellgenerators.com HW4000/HW4000L Portable Electrical Generator Owner’s Manual
6. Soak air filter in clean engine oil.
7. Squeeze out excess oil.
NOTE:
Engine will smoke during initial start-up if too much oil is
left in filter.
8. Reassemble the air cleaner assembly:
For HW4000L Model:
8A. Reinstall the light grey foam air filter.
8B. Reinstall the dark grey foam air filter.
8C. Reinstall the air cleaner cover and lock the latches at
the top and bottom.
For HW4000 Model:
8A. Reinstall the metal air filter plate in the support brack-
ets if it fell out during air filter removal.
8B. Reinstall air filter.
8C. Reinstall air cleaner cover.
FIGURE 40: Oil Air Filter
FIGURE 41: Excess Oil Removal
Frequent or prolonged contact with engine oil may cause
skin cancer.
Thoroughly wash hands and any areas of skin exposed
to used oil with soap and water.
FIGURE 42: Air Filter Installation—HW4000L Model
CAUTION
FIGURE 43: Air Filter Plate Installation—HW4000 Model

Table of Contents

Other manuals for Honeywell HW4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HW4000 and is the answer not in the manual?

Honeywell HW4000 Specifications

General IconGeneral
BrandHoneywell
ModelHW4000
CategoryPortable Generator
LanguageEnglish

Related product manuals