6
Cause of Error
Cause: The detection of short circuit or open circuit of
internal coil sensor during the inspection of main internal
control panel, indicated by “internal coil sensor error”.
Inspection path: Sensor Sensor wire Connectors
Main internal control panel
Tools Required Multimeter, 20K standard sensor (25
Possible Broken Part External coil sensor, outdoor unit control panel
Troubleshooting
Procedures
1. Check if there’s resistance problem, short circuit or open
circuit in the sensor; the resistance value should be
within a reasonable range (15K under the temperature
of 25)
2. Check if the sensor wire is broken.
3. Check if the terminal connectors are well fixed; check if
the weld between the terminal and the main control
panel is loose and pull the terminal slightly for
inspection if necessary.
4. Check if the sensor is damp/wet.
5. If no standard sensor is available, replace the internal
temperature sensor, and then check if the error persists;
if yes, check the main internal control panel and replace
it.
Key Details
DO NOT USE A SENSOR WITH A VALUE LOWER OR
HIGHER THAN 20K
E3 INTERNAL COIL SENSOR ERROR

Other manuals for Honeywell HWAC-1217S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell HWAC-1217S and is the answer not in the manual?

Honeywell HWAC-1217S Specifications

General IconGeneral
BrandHoneywell
ModelHWAC-1217S
CategoryAir Conditioner
LanguageEnglish

Related product manuals