- 1 -
INSTALLATION INSTRUCTIONS
DT-600 Series
COMMAND INPUT/
REMOTE LED ENABLE
Self-Test Initiate
Active Low 0 to 1.5 V
Inactive High 6 to V+ Input
Impedance
110 Kohms (minimum)
TRBL
OPEN COLLECTOR
TROUBLE OUTPUT
1
Vce .3V max @ 50 mA
1K series protection
resistor (For future use)
CMD IN NC C
EOL
2
NO
V-
V+
Models:
DT-640STC
12 m x 12 m (40' x 40')
DT-660STC
18 m x 18 m (60' x 60')
DT-6100STC
30.5 m x 6 m (100' x 20')
Figure 2
DT-600 Wiring
Diagram
1
The Trouble Output is activated when there is a self-test failure, or when an
INFORMER
®
condition occurs. Refer to THE INFORMER CIRCUIT and the
TROUBLESHOOTING THE DT-600 SERIES sections.
2
EOL = End-of-Line (spare) terminal.
NOTE: Reverse polarity will not damage the unit.
POWER
35 mA, 12 VDC
TAMPER SWITCH
Normally Closed
(NC) with cover on
25 mA, 30 VDC
ALARM RELAY
125 mA, 25 VDC
22 ohm series
protection resistor
MOUNTING LOCATION
Select the best location in the room for both technologies. Aim the
DUAL TEC
®
600 series motion sensor toward the interior of the
room, away from windows, moving machinery, and heating/cooling
sources.
Maximum range is obtained at a mounting height of 2.3 m (7'6").
Make sure the sensor has a clear line-of-sight to all areas you wish
to protect. Infrared energy cannot penetrate solid objects. If the
passive infrared (PIR) sensor is blocked, it will not trigger an alarm.
Figure 1
DT-600 Assembly
Figure 3
DT-600 Printed
Circuit Board
CMD INPUT (Jumper W4
off or parked)
REMOTE LED ENABLE
(Jumper is installed)
INSTALLER INITIATED
SELF-TEST
MOMENTARY SHORT
REMOVE JUMPER W2
TO DISABLE LEDs
(Jumper is factory
installed)
DIAGNOSTIC LEDs
AND ALARM LED
INSTALL JUMPER W3 TO
DISABLE INFORMER
(Jumper is factory
installed)
All the walk-test LEDs are located at the bottom, left side of the
sensor. DT-600 sensors are equipped with two diagnostic LEDs:
green for PIR and yellow for microwave. The red LED is used to
indicate an alarm condition.
Apply power to the sensor. Minimize any motion in the area until
the self-test is completed (one minute). Begin walk-testing after all
three LEDs have gone out.
SYSTEM TESTING
NOTE: If the jumper is installed on W3, the LEDs will not flash the
error code and trouble output is disabled when an INFORMER
condition occurs.
TB1
V+
TB2
R69
W3
W4
W1
W2
PLACE JUMPER W1 TO
SET THE ALARM
SEQUENCE (jumper set
to M.A.P. processing = 3
at factory)
MICROWAVE RANGE
ADJUSTMENT THUMBWHEEL
LATCH
WIRING
Observing the proper polarity, wire the sensor as shown below
(use 14 to 22 AWG). Do not leave excess wire inside the unit. Push
as much of the wire as possible back into the wall when returning
the PCB to its housing.
MOUNTING PROCEDURE
To remove the sensor's front cover, use a small slotted screwdriver
to push down on the latch at the top of the unit, while separating the
housing parts.
To remove the printed circuit board (PCB), lift up on the latch at the
top of the unit, while using the microwave antenna to gently pull the
PCB forward.
Securely mount the rear housing at the desired location. When
mounting the sensor on a wall, use the two keyholes in the back of
the rear housing. When mounting the sensor in a corner, use the
breakout tabs on the beveled corners of the unit. A swivel mount
bracket (Model SMB-10) is also available from IntelliSense.
IMPORTANT: To ensure insects do not get inside the DT-600
housing, make sure to seal all knockouts. (Recommended sealant:
silicone RTV.)
NOTE: For proper wiring methods, refer to the National
Electrical Code NFPA 70.
NOTE: Mount at height of 1.2 m (4 feet) when using
Pet-Alley lens.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell IntelliSense DT-640STC and is the answer not in the manual?

Honeywell IntelliSense DT-640STC Specifications

General IconGeneral
BrandHoneywell
ModelIntelliSense DT-640STC
CategoryAccessories
LanguageEnglish

Related product manuals