Honeywell KA 54 - Self-Test Diagnostics

Honeywell KA 54
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
N
KRA 405B RADAR ALTIMETER INSTALLATION MANUAL
Page 3-4
006-10536-0010 Rev. 10 Oct/2005
3.3 SELF-TEST DIAGNOSTICS
SYMPTOM ACTION REQUIRED
Altimeter does not indicate 50
± 5 feet.
The Radar Altimeter System is in-
operative. Repair is required.
Flag does not come into view,
but indicated altitude is cor-
rect.
Indicator Failure. Radar Altime-
ter System failures may not be
indicated by a flag. Repair is
required.
DH Lamp fails to light. Indicator Failure. The decision
height will not
be annunciated.
Repair is required.
The altimeter indicates 100
feet.
The system’s receiver/transmit-
ter is inoperative. Repair is re-
quired.
The altimeter indicates 200
feet.
Configuration module failure. Re-
pair is required. (This is ap-
plicable in systems that have
configuration modules).