Lynx Plus Series Installation and Setup Guide
- 36 -
Data Field Descriptions
91
9191
91
AAV/REM
AAV/REM AAV/REM
AAV/REM
PHN
PHN PHN
PHN
CTRL
CTRLCTRL
CTRL
Audio Alarm Verification (AAV)/ Remote Phone Control
This option is used to enable the Audio Alarm Verification and/or the Remote Phone
Control features.
Notes: (1) In order to activate the Remote Phone Control feature and defeat an answering
machine, ensure that the correct ring detection count (“15”) has been
programmed in field 95.
(2) Remote phone session will be terminated if a report must be sent.
(3) Alarm Audio Verification will only function when Contact ID® is selected. AAV
cannot be used for UL installations.
(4) If an alarm will be reported to primary and secondary phone numbers, AAV
can only function via the secondary number.
(5) If an alarm will be reported to a pager (6-8 in field
49), or to a follow me
phone number (10-12 in field 49) AAV cannot be used.
(6) If AAV is selected and LRR/IP communications device is enabled, you must
enter "0" (primary dialer preferred channel) as the second entry in Field 77.
(7) AAV and Remote Phone Control features can only be used if the central
station or remote phone supports DTMF commands.
SELECTIONS
0 = none
1 = AAV and remote phone control
2 = remote phone control only
4 = AAV only
Field
92: Field *92 is used to program different features in the Lynx Plus and LynxSIA Plus controls. Please be sure
that you use the correct field for the control being installed.
92
9292
92
#
REPS
REPSREPS
REPS
ARM
ARMARM
ARMED
EDED
ED
PER
PERPER
PER
(This field applies only to
the Lynx Plus control)
Number of Reports In Armed Period (
This field applies only to the Lynx Plus control)
This option can be used to limit the number of messages (alarm & alarm restore
reports) sent by the Lynx Plus to the central station in an armed period.
UL installations: must be 1 (unlimited reports)
Lynx Plus SELECTIONS
0 = reports limited to a total of 10
1 = unlimited number of reports
92
9292
92
SWI
SWISWI
SWINGER
NGER NGER
NGER
SHUTDOWN
SHUTDOWNSHUTDOWN
SHUTDOWN
(This field applies only to
the LynxSIA Plus control)
Swinger Shutdown
(This field applies only to the LynxSIA Plus control)
This option is used to define number of alarm reports sent for non-fire zones, after
which the LynxSIA Plus ignores subsequent alarms of the zone during the same armed
period. The zone swinger counter is reset after the zone alarm is erased from alarm
memory (after two CODE + OFF).
Note: The LynxSIA Plus control validates the data entered in this field. If the selection is not
valid the control will emit a single long beep indicating that the selection has been
rejected. The control replaces the selection with the default value, which is displayed
on the keypad, and advances to the next field.
LynxSIA Plus SELECTIONS
1 = shutdown after one alarm
2 = shutdown after two alarms

Table of Contents

Other manuals for Honeywell Lynx Plus Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Lynx Plus Series and is the answer not in the manual?

Honeywell Lynx Plus Series Specifications

General IconGeneral
BrandHoneywell
ModelLynx Plus Series
CategorySecurity System
LanguageEnglish

Related product manuals