ZX Fire Alarm Control Panels MORLEY-IAS
ZX1Se
ZX2Se
Document No. 996-175-000-1, Revision 01
commissioning
manual
ZX5Se
ZX10Se
This manual should not be left with the end user

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Honeywell Morley-IAS ZX5Se and is the answer not in the manual?

Honeywell Morley-IAS ZX5Se Specifications

General IconGeneral
BrandHoneywell
ModelMorley-IAS ZX5Se
CategoryControl Panel
LanguageEnglish

Summary

Introduction

Warnings and Cautions

Safety instructions to prevent injury and equipment damage.

EN54 Information

User Control Levels

Memory Lock

Enabling Level 2 or Level 3 Access

Selecting the commissioning option

Steps to access commissioning functions via Level 3 password.

Commissioning a New Installation

Step 1 – General Setup

Clear panel memory and set factory defaults.

Step 2 – Configure Each Signalling Loop

Auto Learn, device configuration, and zone assignment for loops.

Step 3 – Configure Peripherals (if required)

Auto Learn and configure peripheral devices.

Step 4 – Configure Outputs (sounders and relays)

Program sounder patterns and relay operations.

Step 5 – Configure Day Mode Operation (If required)

Step 6 - Configure Network Options (If required)

Step 7 – Commence Normal Operation

Configure Option

Signalling Loops

Options for configuring signalling loops, including Auto Learn.

Auto Learn

Full Auto Learn

Process for the panel to learn installed devices on a loop.

Zones

Alarm Thresholds (Device Sensitivity)

Device Actions

Peripherals

Auto Learn

Learning devices connected to the RS485 peripheral bus.

Devices

Sounders

Allocating Sounders

Programming sounder ringing patterns and zone assignments.

Pattern ON

Pattern OFF

Pattern DELAY

Pattern DOUBLE KNOCK

Pattern OFF-ON-ON

Pattern PULSE-ON-ON

Overriding Delays at Level 1

Relays

Program Integrity Option

Program a Panel from a PC Using the ‘FIRE' Program

Passwords Option

Day Mode Option

Day Modes

Configuring Delayed, Sensitivity, and Verification modes.

Delayed Mode

Commissioning Delayed Mode

Steps to enable and configure delayed mode.

Sensitivity Mode

Commissioning Sensitivity Mode

Steps to enable and configure sensitivity mode.

Verification Mode

Commissioning Verification Mode

Steps to enable and configure verification mode.

Setup Option

Event Log

Event Logic

System Events Option

Hochiki Multi-Sensor Support

System Sensor/ Morley-IAS Multi-Sensor & Laser Support

Disablement of addressable points

Test Condition

Network Disablement / Enablement

System Sensor/ M-IAS Multi-sensor & Laser detectors