ZX Fire Alarm Control Panels MORLEY-IAS
ZX1Se
ZX2Se
Document No. 996-175-000-1, Revision 01
commissioning
manual
ZX5Se
ZX10Se
This manual should not be left with the end user

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Honeywell Morley-IAS ZX2Se and is the answer not in the manual?

Honeywell Morley-IAS ZX2Se Specifications

General IconGeneral
BrandHoneywell
ModelMorley-IAS ZX2Se
CategoryControl Panel
LanguageEnglish

Summary

Introduction to ZX Fire Alarm Control Panels

Warnings and Cautions

Procedures to avoid injury and damage, user training, and relevant regulations.

User Control Levels

Level Definition Overview

Describes three user control levels for panel operation and access.

Controls and Displays

Control Key Functions

Explains the function of system control keys and interactive keys.

Memory Lock Functionality

Enabling User Access Levels

Selecting the Commissioning Option

Procedure to access commissioning functions using the Level 3 password.

Commissioning a New Installation

Step 1: General Setup

Steps for clearing panel memory and checking/changing default settings.

Step 2: Configure Signalling Loops

Process for configuring loops, including auto-learn and device assignment.

Step 3: Configure Peripherals

Steps for configuring peripheral devices like input/output units.

Step 4: Configure Outputs

Steps for programming sounder and relay outputs.

Step 7: Commence Normal Operation

Final steps before normal operation, including password and memory lock.

Configure Option Details

Accessing the Configure Option

How to access the configuration menu and its primary functions.

Signalling Loops Configuration

Options for configuring individual signalling loops.

Auto Learn for Signalling Loops

Process for the panel to automatically detect devices on a loop.

Peripheral Configuration

Auto Learn for Peripherals

Process for the panel to automatically detect peripheral devices.

Sounder Configuration

Allocating Sounders and Patterns

Programming sounder ringing patterns and zone assignments.

PC Remote Programming

Program Integrity Check

Passwords Option Configuration

Day Mode Operation

Delayed Mode Configuration

Configuring delayed operation for sounders and outputs.

Sensitivity Mode Configuration

Adjusting detector sensitivity based on time of day.

Verification Mode Configuration

Using a delay to reduce false alarms from smoke detectors.

Network Configuration

Supplementary Information

Locating Earth Faults

Methods for identifying and locating earth faults in wiring.