6 www.honeywell.com
Installing the PRO3200 Two-Reader Module
Power
The assignment for each relay status LED is shown in the following table.
Power
The Two-Reader Module accepts 12VDC with an operating range of 10 to 14VDC and consumes a
maximum of 650mA of current. Locate power source as close to this board as possible. Connect power
with minimum of 18AWG wire.The input voltage is regulated to 5VDC.The regulated voltage or the
12VDC (pass through) is available for powering the readers. The selection is made via jumpers and is
available at both reader connectors.
Table 4: Additional PW6000 Two-Reader Module LEDs
LED number Description
D3 Reader 0 activity
D4 Reader 1 activity
D5 Input 0
D6 Input 1
D7 Input 2
D8 Input 3
D9 Input 4
D10 Input 5
D11 Input 6
D12 Input 7
D13 Tamper
D14 Power
D15 Relay 0 status
D16 Relay 3 status
D17 Relay 2 status
D18 Relay 4 status
D19 Relay 1 status
D20 Relay 5 status

Other manuals for Honeywell PRO3200