69-2715EF—07 26
Pre-occupancy purge
This business use feature turns on the
fan 1 to 3 hours before each “occupied”
time period, to provide a comfortable
work environment when you arrive.
Compressor protection
The thermostat keeps the compressor
off for a few minutes before restarting, to
prevent equipment damage. During this “off
time, the message “waiting for equipment”
is displayed on screen.
Auto changeover
This feature is used in climates where both
air conditioning and heating are used on
the same day.
When the system is set to Automatic, the
thermostat automatically selects heating
or cooling depending on the indoor
temperature.
Heat and cool settings must be at least
3 degrees apart. The thermostat will
automatically adjust settings to maintain
this 3-degree separation.
Note: Select Auto Changeover on the
Heating and Cooling System Changeover
screen under Advanced Preferences. See
“Setting advanced preferences” on page
27.