7
PROGRAMMING YOUR ST9400C
Reviewing the Programme Times
To review your hot water programme, move the slider to the HOT WATER position.
To review your heating programme, move the slider to the HEATING position.
To review the programme times, press the
button repeatedly. The appropriate
ON and OFF markers will be displayed to show you which time is being reviewed.
Any of these times can be adjusted by using the or buttons, and then
confirmed using the button. Remember to return the slider to the RUN position
after reviewing is complete.
Modifying the Hot Water Programme
The hot water programme has three pairs of ON/OFF switching times per day. Each
time can be set between 3.00 am and 2.50 am (on the next day) to allow you to
programme the hot water to stay on past midnight, if required.
a. Move the slider to the HOT WATER position. ‘SET HOT WATER’ will show briefly
to verify this action.
b. ‘SET ON-TIME 1’ will then be displayed and the time setting for the first ON 1
time for MONDAY will now be flashing to indicate it can be changed. If you do
not wish to change the time, press the green
button and move to the next
step. If you do wish to make a change, use the or buttons to change
the first ON 1 time. Each press of the button will change the time by 10 minutes.
As soon as the time has been changed, the message ‘ON-TIME 1 OK?’ will be
displayed. Press the green button to confirm the time is correct and move to
the next step. ‘SAVED’ will be displayed for a moment to confirm that any change
has been saved to memory.
HOT WATER HEATING
DAY/TIME
HOT WATER
HEATING
RUN
HOT WATER HEATINGHOT WATER HEATING

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell ST9400C and is the answer not in the manual?

Honeywell ST9400C Specifications

General IconGeneral
ModelST9400C
CategoryTemperature Controller
DisplayLCD
MountingWall-mounted
Number of Channels2
Contact Voltage230V AC
Contact Current3A resistive, 1A inductive
Output TypesRelay
Operating Temperature0°C to 40°C
Switching timesUp to 3 per day
Power supply230V AC
TypeProgrammable Thermostat