VISTA-128BP/VISTA-250BP Installation and Setup Guide
3-20
2K ELOR
2K ELOR
TAMPER SWITCH
(CONTACTS CLOSE WHEN
SWITCH DEPRESSED).
LOCK SWITCH
(NORMALLY OPEN)
+
TO J7 / OUT 2
TO J7 / OUT 4
TO AUX POWER
(TERMINAL 6)
ZONE
ZONE
TO ZONE 7 (+)
(TERMINAL 20)
YELLOW WHITE
GREEN
(READY)
RED
(ARMED)
RED BLACK
820
ohms
820
ohms
J7_keyswitch
Figure 3-25: Remote Keyswitch Wiring
Smoke Detector Reset
Output 1 may be used to reset 4-wire smoke detectors.
Use this output to trigger a low current relay, and wire
the power for the smoke detectors through the relay’s
contacts.
NOTE: The output is normally high (12VDC) and goes
low when the User Code + Off is entered at the
keypad.
To install a relay for smoke detector reset, perform the
following steps:
Step Action
1 Connect power terminals of the relay to the
panel’s auxiliary power (terminals 6 & 7).
2 Connect trigger input of the relay to Output
1 on J7.
3 Connect the “pole” (common) of the relay to
terminal 6 of the control.
4 Connect the positive side of the smoke
detectors to the normally closed contact of
the relay.
5 Connect the negative side of the smoke
detectors to terminal 7 of the control.
Remote Keypad Sounder
This feature is available in the VISTA-128BP
only. An optional Amseco PAL 328N Piezo Sounder
can be used to duplicate the sounds produced by the
keypad's built-in sounder. The panel will remote all
sounds (e.g., alarm, trouble, chime, entry/exit, etc.)
produced by the keypad's built-in sounder except for
the short beeps associated with keypad key
depression. One application of this feature might be to
produce chime sounds at a distant location from the
panel's keypads.
Remote Keypad Sounder Setup
To setup for a remote keypad sounder, connect the
piezo sounder to the panel’s positive auxiliary power
output and to Output 1 on the J7 connector as shown
in Figure 3-26.
To duplicate the keypad sounds for a particular
partition, program that partition number in field ✳15.
Program field 1✳46 Auxiliary Output Enable with a
[2].
1 2 3 4 5 6 7 8 9
GRAY (GROUND)
YELLOW (OUT 1)
WHITE (GROUND)
RED (OUT 2)
GREEN (GROUND)
BROWN (OUT 3)
BLUE (GROUND)
BLACK (OUT 4)
J7 CONNECTOR
IF USED.
1. OUT 1 IS NO LONGER
USABLE FOR SMOKE
DETECTOR RESET
OR GROUND START
(SEE FIELD 1*46).
2. OUT 2 & 4 CAN NO LONGER
BE USED TO PROVIDE
ALARM TRIGGERS.
N/U
4142TR CABLE
BLACK
–
AMSECO PAL-328N
PIEZO SOUNDER
+
RED
TO AUX POWER +
TERMINAL 6
10mA CURRENT DRAIN)
J7_trigcon-001-V1
Figure 3-26: Remote Keypad Sounder Wiring