Section 5 – Data Field Descriptions
5-5
FIELD
TITLE and DATA ENTRIES EXPLANATION
*40
Enable Open/Close report for
Keyswitch
0 = disable
1 = enable
If enabled, whenever the keyswitch is used to arm or disarm the partition, an
open/close report is sent to the central station.
*41
Normally Closed or EOLR (Zones
2-8)
0 = EOLR used
1 = normally closed
If 0, end-of-line resistors must be used on zones 2-8.
If 1 end-of-line resistors cannot be used and only normally closed devices
must be used.
Must be 0 for UL installations.
*42
Dial Tone Pause
Enter the wait time for dial tone detection:
0 = 5 seconds; 1 = 11 seconds; 2 = 30
seconds.
Enter the time the system waits for dial tone before dialing. Applies if true dial
tone is not selected in field *43.
Must be 0 for UL installations.
*43
Dial Tone Detection
0 = disable
1 = enable
If enabled, the system waits for true dial tone. If no dial tone is detected, control
dials at end of pause programmed in field *42.
If disabled, the system pauses for seconds entered in field *42, then dials.
NOTE: Disabling may be necessary in high-noise environment telco networks
where noise can be confused with dial tone, resulting in premature dialing.
*44
Ring Detection Count
Enter 00 to disable ring detection.
Enter 01-14 for ring counts of 1-14.
Enter 15 to select Answering Machine Defeat
Mode
Only applicable if using a 4285/4286 VIP Module and/or if station-initiated
downloading will be used.
NOTES:
Do not enter 00 if a 4285/4286 is installed.
In the Answering Machine Mode, the caller should let the phone ring once, then
hang up, and call again within 30 seconds. The system, upon hearing one ring
followed by nothing, does not answer the first call, but readies itself to pick up
on the first ring of the next incoming call that is received within 30 seconds (i.e.,
the downloader calling again).
Must be 00 for UL installations.
*45
Primary Format
0=Low Speed; 1=Contact ID; 2=ADEMCO
High Speed; 3=ADEMCO Express
Enter the reporting format for the primary telephone number.
*46
Low Speed Format (Primary)
0 = ADEMCO Low Speed
1 = Sescoa/Radionics
Enter the low speed format for the primary telephone number.
*47
Secondary Format
0=Low Speed; 1=Contact ID; 2=ADEMCO
High Speed; 3=ADEMCO Express
Enter the reporting format for the secondary telephone number.
*48
Low Speed Format (Secondary)
0 = ADEMCO Low Speed
1 = Sescoa/Radionics
Enter the low speed format for the secondary telephone number.
*49
Checksum Verification
Enter 2 digits, one for the primary and one for
the secondary.
0 = disable
1 = enable
If enabled, the system for either or both primary/secondary formats sends a
verification digit to validate the message at the receiver without having to send
two message rounds. Selection is valid for 3+1, 4+1, and 4+2 reports.
*50
Sescoa/Radionics Select
0 = Radionics
1 = Sescoa
Radionics selection uses hexadecimal 0-9, B-F reporting.
Sescoa selection uses only numeric reporting (0-9).
NOTE: The selection applies to both primary and secondary phone numbers.