Section 5 – Data Field Descriptions
5-7
FIELD
TITLE and DATA ENTRIES EXPLANATION
*84
Swinger Suppression (partition-
specific)
Enter 01-15.
Enter 00 for unlimited reports
This option limits the number of messages (alarms or troubles) sent for a
specific zone in an armed period. The system automatically resets the
shutdown for a zone after 48 hours if there are no trips on any zone.
Must be 00 for UL installations.
*85
Enable Dialer Reports for Panics
& Duress (partition-specific)
0 = disable
1 = enable
This field has four entries as follows: Zone 995, 996, 999, Duress Enable for
each partition that the panics and duress reporting is desired.
NOTE: Non-zero report code must be assigned to zone 992 (duress) to enable
Duress reporting.
If you enable any of the panics to report, make sure field *22 is programmed
correctly for each partition.
*87
Entry Warning (partition-specific)
0 = 3 short beeps
1 = slow continuous beeps
Select the type of warning for the entry delay period.
*88
Burglary Alarm Communicator
Delay (partition-specific)
0 = no delay
1 = 30-second delay
Select the delay, if any, for burglary alarm communications.
Must be 0 for UL installations.
SIA Guidelines: Must be 1.
*89
Restore Report Timing
0 = instant
1 = after bell timeout
2 = when system is disarmed
Select the time when restore reports are sent after an alarm.
Must be 2 for UL installations.
*90
Secondary Subscriber Account
Number (partition-specific)
Enter 00-09; B-F (11-15)
Enter a 3- or 4-digit (depending on report format) primary subscriber account
number. Each number requires a 2-digit entry so as to allow entry of
hexadecimal digits (B-F). If a 3-digit account number is to be used, enter data
only in the first 3 locations, and enter * in the fourth location.
NOTE: This field
must
be programmed if a secondary phone number is used
(field *34). This account number can be the same as the primary account
number.
1*07
Check or TRBL Display
0 = CHECK
1 = TRBL
Select whether the system should display TRBL or CHECK for trouble
conditions.
1*10
First to Alarm Display Lock
0 = scroll alarms
1 = lock display
If lock display is selected, the system displays of first fire alarm and requires the
user to press the [*] key for a display of each additional fire alarm. Otherwise,
the system automatically scrolls all fire alarms.
1*15
Cancel Verify
0 = disable
1 = enable
If enabled, the system pulses the alarm output three times and displays “Cancel
Sent to Central Station” when it receives a “kissoff” of a Cancel report from the
central station This message can only be cleared by entering the code + off.
Enter 0 to disable.
NOTE: Field 1✳52 determines when a Cancel report is sent to the central
station.
1*17
Lobby Partition
0 = none
1-8 = partition number
Select the Common Lobby Partition.
1*18
Affects Lobby (partition-specific)
0 = disable
1 = enable
If enabled, causes lobby partition to disarm when this partition disarms.
NOTE: This partition must be armed before lobby can be armed.