Barcode 171
E-EQ-VX6RG-F VX6 Reference Guide
Step 9: Code ID
Access: Start | Settings | Control Panel | Scanner | Barcode | Symbology
Settings
If the Code ID is not stripped, the Code ID is added to the output buffer after the Prefix string (if
any).
Figure 4-18 Code ID Strip
The default is to enable Code ID stripping (the checkbox is enabled and the Code ID is not added
to the output buffer).
The Code ID is stripped from the barcode data for the Symbology selected from the pulldown list.
If ‘All’ is selected, the Code ID stripping is applied to all symbologies that have not been
previously customized.

Table of Contents

Other manuals for Honeywell VX6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell VX6 and is the answer not in the manual?

Honeywell VX6 Specifications

General IconGeneral
Print TechnologyThermal Transfer
Print Resolution300 dpi
Memory128 MB Flash
ConnectivityUSB, Ethernet, Serial
RAM128 MB SDRAM
Storage128 MB Flash
PortsUSB, Ethernet, Serial