20
FAULT CODES & DIAGNOSTICS
If an error is detected in programme, the programme will be terminated and one of the following errors
will be displayed on the LCD.
In the event of any of the above codes being displayed, after the fault has been rectified it will be
necessary to reset the machine. This is achieved by pressing and holding the Start/Reset button.
After a few seconds the fault code will be replaced with dashes on the LCD display.
Fault
Code
Fault Possible Cause(s)
AL 01 Overflow (water in base
pan).
Leak from water line.
AL 02 Solenoid valve broken. Inlet valve, letting by, heater Earth fault, open circuit
heater
AL 03 Time out draining Pump connections, blockage, module
AL 04 Thermistor circuit Thermistor c/w timer
AL 05 Filters blocked Mesh plate, filter or microfilter, pressure sensor, pressure
switch, circulation pump
AL 06 Time out filling Inlet valve, connections, timer, water turbine
AL 08 Time out heating NTC detached from casing
AL 09 Software recognition
error
Timer not programmed, wrong keypad
AL 10 Heating circuit Heating element, connections, module, relay.
AL 99 Communication
problem
Bit100 Timer Card, delay or connecting cable
H20 Time out filling Customers tap not turned on