TEST PROGRAMME
The following test programme can be used if a fault is suspected within the appliance. There are two
test that can be carried out - a 5 minute and a 20 minute test.
Each of the two tests performs the same functional check of components with the 20 minute test
heating the water to 55°C, verifying the operation of the heater and thermistor.
Selecting the Test Programme
1. Ensure that the dishwasher is switched On and check that no programme is selected.
2. Press the Programme button (P) once.
3. Press the Stand-by button. The display will switch Off.
4. Immediately press the Stand-by button. The display will switch On.
5. Press the Programme button (P) once.
6. Press the Stand-by button. The display will switch Off.
7. Immediately press the Stand-by button. The display will switch On. The Pre-Wash and Drying
symbols will be flashing.
Long Test
1. Press the Programme button (P) once. The Wash and Rinse symbols will be displayed.
2. Press the Start/Reset button. 'ROD' will be displayed and the test programme will be carried out.
3. At the end of the test, the buzzer sounds twice and 'END' is displayed. Pressing the (P) button
will then enable the programmes to be selected as normal.
Short Test
1. Press the Programme button (P) twice. The Wash and Rinse symbols will be displayed.
2. Press the Start/Reset button. 'TEST' will be displayed and the test programme will be carried out.
3. At the end of the test, the buzzer sounds twice and 'END' is displayed. Pressing the (P) button
will then enable the programmes to be selected as normal.
To cancel a test programme in progress, press and hold the Start/Reset button. The buzzer will
sound three times and cancel the test programme.
FITTING NEW 100 BIT CONTROL CARDS
When a 100 bit control card is first fitted, it may go straight into a factory test cycle.
To eliminate the test cycle: -
Switch On the machine and with the door closed.
Wait for the test cycle to start up (2 LEDs will start to flash).
Switch Off the machine with the door still closed and wait for 15 seconds.
Switch On the machine.
Reset the test cycle by turning the selector knob to reset and leave for 5 seconds.
Note: - all actions are to be carried out quickly and the 15 seconds must be exact.