26
Note: - Due to software changes this chart should only be used as an indication only.
Circulate in Alternating Valve Position 1 X 8'
Circulate in Alternating Valve Position 1 X X 6'
Circulate in Alternating Valve Position 1 X X 120''
Circulate in Alternating Valve Position 1 X X
Drain X X 60''
Drain and reset alternating wash valve to Position 0 X X 15'' Open
Fill 2 litres static via water turbine X
Verify Pressure Switch Closed X Closed
Fill 2 Litres via water turbine & Circulate X
Fill further 2 Litres if Pressure Switch is open
maximum 2 minutes
X 120'' Closed
Circulate Alternating Valve Position 1 X X 60''
Drain X 60''
Drain and reset alternating wash valve to Position 0 X 15'' Open
WARM RINSE
Fill 2 litres static via water turbine X X
Verify Pressure Switch Closed X X Closed
Fill 2 Litres via water turbine & Circulate X X
Fill further 2 Litres if Pressure Switch is open
maximum 2 mins
X X 120'' Closed
Circulate & Pulse Heater On 10 Secs Off 20 Secs X X 3'
Circulate Alternating Valve Position 2 X X X 6'
Drain XX60''
Drain and reset alternating wash valve to Position 0 X X 15'' Open
HOT RINSE
Fill 2 litres static via water turbine X X X X X X
Verify Pressure Switch Closed X X X X X X Closed
Fill 2 Litres via water turbine & Circulate X X X X X X
Fill further 2 Litres if Pressure Switch is open
maximum 2 minutes
X X X X X X 120" Closed
Heat & Circulate Alternating Valve Position 2 X48°C X48°C X48°C X48°C
Heat & Circulate Alternating Valve Position 2
& Verify Pressure Sensor Closed
X48°C X48°C X50°C X
Verify for Rinse Aid XXX X XXX
Dispense Rinse Aid X X X X X X X
Verify for Rinse Aid XXX X XXX
Heat & Circulate Alternating Valve Position 2 X62°C X6
/68°C
X62
/68°C
Heat & Circulate Alternating Valve Position 2
& Verify Pressure Sensor Closed
X62
/68°C
X62
/68°C
X62
/70°C
X62
/68°C
X
Circulate Alternating Valve Position 2 X 8'
Circulate Alternating Valve Position 2 X X X X X X 5'
DRYING
Regeneration X X X X X X 60''
Pause XXX XXX 4'
Drain XXX XXX 60''Open
Fan/Air Drying X 30'
Fan/Air Drying X1'
Fan/Air Drying X X X 20'
Fill 1 Litre XXX XXX
Drain XXX XXX 30''Open
Circulate X X X X 60''
Drain X X X X 30'' Open
Fill 1 Litre XXX XXX
Drain X X X X 30'' Open
Circulate X X X X 60''
Drain and reset alternating wash valve to Position 0 X X X X X X X X X 30'' Open
Fill 600ml if Salt light On X X X X X X X X X
Reset XXXXXXXXX
Intensive
Eco
Normal
Fast
Pre-Wash
Crystal
Auto Duo
Pressure Sensor
Guest
Time
Pressure Switch
Drying
Selected
Normal
Special