Page 34
SPA SPECIFICATIONS
Spa Model Footprint
Dimension
Height Effective
Filter
Area
Heater
(Watts)
Water
Capacity
Dry
Weight
Filled
Weight*
Dead
Weight*
Electrical Requirements
GLEAM
(Model GLM)
Seats 8
Adults
9'2" x 7'7"
2.79 m
x
2.31 m
38"
97 cm
100
square
feet
4,000 510 gallons
1,925 liters
1,270 lbs.
575 kg
6,925 lbs.
3,140 kg
120 lbs
per sq.
foot
230 volt, 50 or 70 amp Single
phase GFCI protected circuit
PULSE
(Model PLS)
Seats 7
Adults
7'5" x 7'5"
2.26 m
x
2.26 m
38"
97 cm
65
square
feet
4,000 380 gallons
1,450 liters
990 lbs.
450 kg
5,385 lbs.
2,460kg
120 lbs
per sq.
foot
230 volt, 50 amp Single
phase GFCI protected circuit
FLAIR
(Model FLR)
Seats 6
Adults
7'0" x 7'0"
2.13 m
x
2.13 m
36"
91 cm
65
square
feet
4,000 310 gallons
1,175 liters
930 lbs.
420 kg
4,565 lbs.
2,075 kg
115 lbs
per sq.
foot
230 volt, 50 amp Single
phase GFCI protected circuit
BOLT
(Model BLT)
Seats 4
Adults
6'8" x 6'8"
2.03 m
x
2.03 m
33"
84 cm
65
square
feet
1,500
or
6,000
290 gallons
1,100 liters
700 lbs.
320 kg
3,820 lbs.
1,740 kg
105 lbs
per sq.
foot
115 volt, 20 amp dedicate
GFCI protected circuit
OR
230 volt, 50 amp Single
phase GFCI protected circuit
GLOW
(Model GLW)
Seats 4
Adults
6'4" x 7'0"
1.93 m
x
2.13 m
33"
84 cm
65
square
feet
4,000 270 gallons
1,025 liters
700 lbs.
320 kg
3,650 lbs.
1,665 kg
100 lbs
per sq.
foot
230 volt, 50 amp Single
phase GFCI protected circuit
WARNING: Watkins Manufacturing Corporation suggests a structural engineer or contractor be consulted before the spa is placed on an elevated deck.
* IMPORTANT: The "Filled weight" and "Dead weight" of the spa includes the weight of the occupants (assuming an average occupant weight of 175lbs).
Service Information