What does it mean when my Hoymiles HAS-3.0LV-EUG1 Inverter shows an ISO Fault?
- AAmanda RamseyAug 28, 2025
An ISO Fault on your Hoymiles inverter indicates that the insulation impedance of the PV string to the ground is too low. To address this: 1. Use a multimeter to determine if the resistance between the earth and the inverter frame is close to zero. If not, please ensure that the connection is good. 2. If the humidity is too high, an isolation fault may occur. Attempt to restart the inverter. If the fault persists, check it again when the weather turns fine. 3. Check the resistance to ground from the PV module/ cable. Take corrective measures in case of leading to a short circuit or damaged insulation layer. If the alarm persists, contact Hoymiles technical support team.