Open Energy for All
Single-phase Microinverter
HMS-300-1T
HMS-350-1T
HMS-400-1T
HMS-450-1T
HMS-500-1T
USER MANUAL
Region: Europe V202201 hoymiles.com

Other manuals for Hoymiles HMS-300-1T

Questions and Answers

  • K
    Karen AndersonAug 7, 2025
    What to do if my Hoymiles HMS-300-1T Inverter has a firmware error?
    • B
      Brenda WilliamsAug 7, 2025
      Check if the Hoymiles Inverter firmware is correct and has been upgraded. Then, check the communication between the DTU and the Hoymiles monitoring system, and between the DTU and the microinverter. Try again after checking the communication. If the fault persists, further assistance may be needed.
  • A
    andrewgonzalezAug 11, 2025
    What to do if my Hoymiles Inverter shows grid overvoltage?
    • D
      Donald MejiaAug 12, 2025
      If the Hoymiles Inverter alarm occurs occasionally, the grid voltage may be temporarily abnormal, and the microinverter should automatically recover once the grid voltage returns to normal. If the alarm occurs frequently, verify that the grid voltage is within the acceptable range. If it's not, contact your local power operator or, with their consent, adjust the grid overvoltage protection limit in the grid profile via the Hoymiles monitoring system.
  • G
    George OliverAug 16, 2025
    What to do if my Hoymiles HMS-300-1T Inverter shows 10 min value grid overvoltage?
    • T
      Todd MaddenAug 16, 2025
      If the Hoymiles Inverter alarm occurs occasionally, the grid voltage may be temporarily abnormal, and the microinverter should automatically recover once the grid voltage returns to normal. If the alarm occurs frequently, verify that the grid voltage is within the acceptable range. If it's not, contact your local power operator or adjust the grid overvoltage protection limit via Hoymiles monitoring system with their consent.
  • J
    Jason GoodmanAug 19, 2025
    Why is my Hoymiles HMS-300-1T offline?
    • S
      Shannon ChaseAug 20, 2025
      First, ensure the Hoymiles microinverter is working correctly by checking if the DC voltage is within the normal range and confirming the LED indicator status. Next, verify that the serial number (SN) on the microinverter label matches the one on the monitoring platform. Then, check the communication status between the DTU and the Hoymiles monitoring system, as well as between the DTU and the microinverter. If the communication is poor, try to improve it. If the alarm persists and cannot be resolved, further assistance may be needed.
  • J
    John ChanAug 25, 2025
    How to troubleshoot over temperature protection on a Hoymiles HMS-300-1T Inverter?
    • J
      Joshua ColeAug 25, 2025
      Check the ventilation and ambient temperature at the Hoymiles microinverter's installation location. If ventilation is poor or the ambient temperature exceeds the limit, improve ventilation and heat dissipation. If the problem persists with adequate ventilation and temperature, further assistance may be needed.
  • G
    gibsonrobertAug 28, 2025
    What to do if my Hoymiles Inverter was shut down by remote control?
    • A
      Anthony HigginsAug 29, 2025
      Check the status of zero export management and whether the Hoymiles microinverters were manually shut down. If the alarm still persists, further assistance may be needed.
  • G
    Guy MillerSep 2, 2025
    What to do if there is a grid configuration parameter error on my Hoymiles HMS-300-1T Inverter?
    • M
      Michael GarzaSep 2, 2025
      Check if the grid configuration parameter is correct and upgrade it. If the fault still exists, further assistance may be needed.

Hoymiles HMS-300-1T Specifications

General IconGeneral
ModelHMS-300-1T
Rated Power300 W
Input Voltage Range16 V - 60 V
Max. Input Voltage60V
Start-up Voltage16V
Output Voltage230 V
Power Factor>0.99
THD<3%
Ambient Temperature Range-40°C to +65°C
Operating Temperature Range-40°C to +65°C
Weight1.5kg
Enclosure RatingIP67
Protection ClassI
Cooling MethodNatural Convection
Number of MPPT Trackers1
MPPT Voltage Range16V-60V
Nominal Output Voltage/Range230 V
Nominal Output Frequency/Range50 Hz
Max. Output Current1.3A
Max. Units per Branch16 units
Efficiency96.5%
Peak Efficiency96.7%
Dimensions (W×H×D)182mm x 164mm x 29.5mm
Dimensions182mm x 164mm x 29.5mm