Note:
·
If the battery has integrated a readily accessible internal DC breaker, then no additional ① DC breaker is required.
© 2023 Hoymiles Power Electronics Inc. All rights reserved.
04
AC-coupled Inverter Quick Installation Guide
·
The use of
⑦⑧
30 mA RCD is recommended but not mandatory; please comply with local regulations for the system installation.
Model
HAT-5.0HV-EUG1
25 A/600 V
DC Breaker
HAT-6.0HV-EUG1
HAT-8.0HV-EUG1
HAT-10.0HV-EUG1
25 A/600 V
DC Breaker
40 A/600 V
DC Breaker
40 A/600 V
DC Breaker
20 A/400 V
AC Breaker
25 A/400 V
AC Breaker
32 A/400 V
AC Breaker
32 A/400 V
AC Breaker
Depends
on Loads
Main
Breaker
30 mA
RCD
① ② ④ ⑤ ⑦⑧③
16 A/400 V
AC Breaker
16 A/400 V
AC Breaker
20 A/400 V
AC Breaker
25 A/400 V
AC Breaker
16 A/400 V
AC Breaker
16 A/400 V
AC Breaker
20 A/400 V
AC Breaker
25 A/400 V
AC Breaker
⑥
E-BAR
Battery
BMS
Backup
Loads
Smart
Meter
1
RCD
Grid
Normal Loads
Distribution Box
PE or
L1
L2
L3
N
L1
L2
L3
N
PE
EPS
GRID
Meter
L1
L2
L3
N
PE
L1
L2
L3
N
PE
L1 L2 L3 N PE
CT1
CT2
CT3
Utility
meter
RCD
ʙ
ʒ
ʓ
ʕ
ʗ
ʘ
Do not connect this terminal
when the neutral wire and PE
wire are connected together.
N-BAR
E-N
Link
HAT-HV series
ʖ
Generator
/Inverter
GEN
L1
L2
L3
N
PE
CT1
ʔ
Smart
Meter
2
CT2
CT3
L1
L2
L3
N
PE
LOAD GRIDLOAD GRID
or
Do not connect this terminal
when the neutral wire and PE
wire are connected together.
RJ45
Coupler
INV GENINV GEN