14-24
Configuring and Monitoring Port Security
MAC Lockdown
Figure 14-14.Example showing a MAC Address cleared from the MAC Address Table.
MAC Lockdown
MAC Lockdown, also known as “static addressing,” is the permanent assign-
ment of a given MAC address (and VLAN, or Virtual Local Area Network) to
a specific port on the switch. MAC Lockdown is used to prevent station
movement and MAC address hijacking. It also controls address learning on
the switch.
Locking down a MAC address on a port and a specific VLAN only restricts the
MAC address on that VLAN. The client device with that MAC address is
allowed to access other VLANs on the same port or through other ports.
Note Port security and MAC Lockdown are mutually exclusive on a given port. You
can either use port security or MAC Lockdown, but never both at the same
time on the same port.
HP Switch(config)# show mac-address vlan 2
Status and Counters - Address Table - VLAN 2
MAC Address Located on Port
------------- ---------------
00000c-07ac00 2
000102-03db12 2
0001e6-b197a8 2
HP Switch(config)# clear mac-address vlan 2 mac 0001e6-b197a8
HP Switch(config)# show mac-address vlan 2
Status and Counters - Address Table - VLAN 2
MAC Address Located on Port
------------- ---------------
00000c-07ac00 2
000102-03db12 2
Syntax: [no] static-mac < mac-addr > vlan < vid > interface < port-number >

Table of Contents

Other manuals for HP 3500yl Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 3500yl Series and is the answer not in the manual?

HP 3500yl Series Specifications

General IconGeneral
Input Voltage100-240 VAC
Ports24/48 x 10/100/1000 ports (depending on model)
Uplink Ports4 x SFP ports
LayerLayer 3
ManagementCLI, Web, SNMP
Routing ProtocolRIP, OSPF, BGP
Operating Temperature0°C to 45°C
StackingYes
Memory512 MB
VLAN SupportYes
Layer 3 RoutingYes
Security FeaturesACLs, 802.1X
Power SupplyInternal
Power over Ethernet (PoE)Optional