EasyManua.ls Logo

HP 3PAR StoreServ 7200 2-node - Changing Virtual Volume Fault-Tolerance Levels; Fully-Provisioned Virtual Volumes; Thinly-Provisioned Virtual Volumes; Changing Virtual Volume Parameters

HP 3PAR StoreServ 7200 2-node
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Tune the user space of the volume by issuing the tunevv usr_cpg <CPG_name>
<volume_name> command, where:
usr_cpg <CPG_name> is the name of the CPG created previously in Step 1, indicating
the user space of the new CPG will be used.
<volume_name> is the fully-provisioned virtual volume you are modifying.
3. Tune the snapshot space of the volume by issuing the tunevv snp_cpg <CPG_name>
<volume_name> command:
snp_cpg <CPG_name> indicates the CPG to where the snapshot space is moved.
<volume_name> is the fully-provisioned virtual volume you are modifying.
Changing Virtual Volume Fault-Tolerance Levels
Thinly-Provisioned Virtual Volumes
To change the volume fault-tolerance level of a TPVV, perform the following:
1. Create a new CPG with the desired fault-tolerance level and RAID type. See “Creating a
Common Provisioning Group (page 80) for instructions.
2. Change the TPVV’s fault-tolerance level by issuing the tunevv usr_cpg <CPG_name>
<TPVV_name> command, where:
usr_cpg <CPG_name> is the name of the CPG created previously in Step 1.
<TPVV_name> is the TPVV you are modifying.
Fully-Provisioned Virtual Volumes
To change the volume fault-tolerance level of a fully-provisioned virtual volume, perform the following:
1. Create a new CPG with the desired fault-tolerance level and RAID type. See“Creating a
Common Provisioning Group (page 80) for instructions.
2. Change the fully-provisioned virtual volume’s fault-tolerance level by issuing the tunevv
usr_cpg <CPG_name> <volume_name> command, where:
usr_cpg <CPG_name> is the name of the CPG created previously in Step 1.
<volume_name> is the fully-provisioned virtual volume you are modifying.
3. Tune the snapshot space of the volume by issuing the tunevv snp_cpg <CPG_name>
<volume_name> command:
snp_cpg <CPG_name> indicates the CPG to where the snapshot space is moved.
<volume_name> is the fully-provisioned virtual volume you are modifying.
Changing Virtual Volume Parameters
Thinly-Provisioned Virtual Volumes
To change the parameters of a TPVV, perform the following:
1. Create a new CPG with the parameters you wish to apply to the volume. See “Creating a
Common Provisioning Group (page 80) for instructions.
2. Issue the tunevv usr_cpg <CPG_name> <TPVV_name> command, where:
usr_cpg <CPG_name> is the name of the CPG created previously in Step 1.
<TPVV_name> is the TPVV you are modifying.
Fully-Provisioned Virtual Volumes
To change the parameters of a fully-provisioned virtual volume, perform the following:
176 Performance Tuning