16
{ Data bits—8.
{ Parity—None.
{ Stop bits—1.
{ Flow control—None.
{ Emulation—VT100.
If the console port settings change, change the terminal settings accordingly.
2. If the problem persists, contact HP Support.
Failures during operation
Symptom
A failure occurs when the blade switch is operating.
Solution
To resolve the problem:
1. Execute related commands at the CLI to display blade switch operating information and locate the
fault.
2. If a configuration error is found, re-configure the switch, perform configuration rollback, or restore
the factory-default settings.
For example, if an incorrect IP address is configured for an interface, you can use the undo ip
address command in interface view to delete the IP address and configure a new one.
If multiple configuration errors need to be rectified, you can perform configuration rollback to roll
back the switch to the specified configuration status without rebooting the switch. For more
information about configuration rollback, see HP 6125XLG Blade Switch Configuration Guides
and HP 6125XLG Blade Switch Command References.
3. If the problem persists, contact HP Support.
IRF member device failure
Symptom
An IRF member device fails and needs to be replaced.
Solution
To resolve the problem:
1. Prepare a device that is the same model as the failed one.
2. View the startup configuration file saved on an IRF member device that is operating correctly.
Record the IRF member ID of the failed device and how the IRF physical interfaces on the failed
device are bound to the IRF ports.
3. From the OA module on the enclosure, power off the failed device.
4. Record the cable connection positions on the failed device and remove all cables from the failed
device.
5. Install the new device in the enclosure. The device powers on automatically.