Table 6·3. 
Flexible Disk Drive Configuration Bottom  Jumper Functions 
Jumper  Function 
Label 
ID2,IDl, 
SCSI Bus Address jumpers. 
IDO 
ID2 is  most significant bit. 
Default settings:  Address 
3. 
ID2 = out; 
IDI 
= in; 
IDO 
= in. 
EJC 
Eject mode 
In 
= Electrical eject mode (not used). 
Out 
= (default) Manual eject mode. 
LEV 
Pin 
2 
output 
of the density is enabled. 
In 
= enabled.  (Default) 
Out 
= disabled. 
HDS  In 
= enabled.  (Default) 
Out 
= disabled. 
STL 
In 
= enabled.  (Default) 
Out 
= disabled. 
PAR 
Enable 
Parity 
In 
= enabled.  (Default) Controls parity checking of 
data 
on SCSI bus. 
Out 
= disabled. 
MaN 
Motor ON 
In = disabled. 
Out 
= enabled. 
(Default) Drive motor is not turned 