For
HP
Internal Use
Only
Table 5-41. Integrated Access Port Selftest Failure Codes (continued)
Element
Part
Under
Description Destructive
Number
Test
Test
100
OCT
ART
Test interr. priority in channel x.
No
101-107 Reserved.
108
OCT
ART
Test break features in channel x.
No
109-115 Reserved.
116
OCT
ART
Test timer features in channel x.
No
117-123 Reserved.
124
OCT
ART
Test xon/xoff features in channel x
No
125-131 Reserved.
132
ADP
Check
channel hardware (Adp)
port
x.
No
133-139
Reserved.
140 ADP
Check
global link
at
CREM
input
on
Yes
ADP.
141
Complete test
of
8-port MUX and RS232 ADP
Yes
142
Complete test of
ADP
only
Yes
143
Complete test
of
8-port MUX and RS422
ADP
Yes
144-251
Available.
252
Returns
MUX id., plus added info.
No
253
Returns AD
P type ( quadriloop or not).
Yes
254
Backplane loopback (through QANAT).
Yes
255
Get the rest
of
error
data
structure.
Yes
5-42 Troubleshooting