92 Chapter 3 System Error Codes
System Error Codes
• Check if the Curing IR Temperature sensor is dirty and requires cleaning, use the cleaning
procedures described in the User’s Guide while observing all safety precautions while working in
the area of the heaters.
• Check if there is an obstacle blocking the view of the Curing IR Sensor. Check that it is correctly
installed with no interference in the IR path.
• Check the power going to the Curing IR temperature sensor. A good indication is that the blue LED
on the sensor’s body will light if the sensor is pointing to an object warmer than 30C.
• Check the position of the Curing IR temperature sensor is correct, if it is pointing to a position other
than the substrate this will cause an error.
• Perform the IR sensor check diagnostic “8.4 Curing IR sensor” ⇒Page 170, to check the values being
detected by the IR sensor. Replace the Curing IR sensor if required ⇒Page 510.
• Replace the Heaters Control Assembly ⇒Page 465.
SE Code: 16.05:00 - Problem with the Curing System Temperature Sensor
Problem Description:
Signal error detected with the Curing System Temperature Sensor.
Corrective Action:
• Check the Curing IR Sensor Fan is turning and is correctly installed with the fan in the correct
orientation.
• Check the cables are connected and not damaged.
• Replace the Curing IR Sensor & Fan ⇒Page 510.
• Replace the Printmech ⇒Page 482.
• check if the Curing IR sensor is dirty and requires cleaning, use the cleaning procedures described
in the User’s Guide while observing all safety precautions while working in the area of the heaters.
• Check the power going to the IR sensor. A good indication is that the blue LED on the sensor’s body
will light if the sensor is pointing to an object warmer than 30c.
• Perform the IR sensor diagnostic check “8.4 Curing IR sensor” ⇒Page 170, to check the values being
detected by the IR sensor. Replace the Curing IR sensor if required ⇒Page 503.
SE Code: 16.06:00 - Temperature error detected
Problem Description:
There is a mismatch between the temperature detected by the Curing IR Sensor and the amount of
electrical power the Curing System is receiving
Corrective Action:
• The ink density is too high, check the User´s Manual for the recommended ink density levels.
• The input voltage is in the range of 198v to 205v, ensure the ambient temperature is higher than
20C for the functioning of the printer.
• Check if there is an obstacle blocking the view of the Curing IR Sensor. Check that it is correctly
installed with no interference in the IR path.
• Check if the substrate loaded on the printer is too transparent or reflective for the IR sensor to
detected the surface temperature. Check this by loading another type of substrate.