Continuable and Non-Continuable Error Codes 91
System Error Codes
SE Code: 16.02:00 - Curing system cool down time out
Problem Description:
Curing System unable to cool down in the pre-defined amount of time.
Corrective Action:
• Check there are no obstructions on any of the cooling fans: Curing, Top Cover Fans, Rear Fans.
• Check the cables of the fans are not damaged and are connected. Replace any fans if required: Top
cover fans ⇒ Page 349. Rear Fans ⇒Page 351 . Curing Fans ⇒Page 503.
• The environmental ambient temperature is too hot or is outside the operational specification of the
printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, heaters
etc.
SE Code: 16.03:00 - Curing system temperature too high
Problem Description:
Curing System has exceeded the upper temperature level (150C).
Corrective Action:
• Check there are no obstructions on any of the cooling fans: Curing, Top Cover Fans, Rear Fans.
• Check the Curing IR Sensor Fan is turning and is correctly installed with the fan in the correct
orientation.
• Check the cables are connected and not damaged.
• Replace the Curing IR Sensor & Fan ⇒Page 510.
• Replace the Printmech ⇒Page 482.
• The Curing IR sensor is dirty and requires cleaning, use the cleaning procedures described in the
User’s Guide while observing all safety precautions while working in the area of the heaters.
• Check the power going to the Curing IR sensor. A good indication is that the blue LED on the
sensor’s body will light if the sensor is pointing to an object warmer than 30C.
• Check the position of the Curing IR sensor is correct, if it is pointing to a position other than the
substrate this will cause an error.
• Perform the Curing IR sensor diagnostic check “8.4 Curing IR sensor” ⇒Page 170, to check the
values being detected by the Curing IR sensor. Replace the Curing IR sensor if required ⇒Page 510.
• Ensure there are no other addition external sources of heat, such as strong sunlight, powerful lights
or heaters.
SE Code: 16.04:00 - Curing system temperature too low (below 5C)
Problem Description:
Curing System has exceeded the lower temperature level.
Corrective Action:
• Check if the environmental ambient temperature is low. Check the surrounding temperature is within
the printer´s operating specifications; it should be higher than 15C for correct printer operation. If
this is the case, increase the ambient temperature of the printer´s location.