Continuable and Non-Continuable Error Codes 105
System Error Codes
Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
Clean the OMAS window Page 602.
Perform the OMAS check service test Page 189.
Replace the OMAS Page 424.
SE Code: 50:03 - Internal electrical connection problem
Problem Description:
FW error in DSP or Engine code or link is broken between PCAs.
Corrective Action:
There is a tendency for this system error to being displayed because of cables becoming
disconnected. Check all relevant cables are correctly connected, especially the cables from the
OMAS Controller and the Main PCA and the Sausalito PCA.
Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
Check that the Printer has the latest Firmware version, if not, update the firmware to the latest
version.
Replace the OMAS Controller Card Page 437
Replace the OMAS Module Page 424
SE Code: 50.01:10 - Connection problem with OMAS
Problem Description:
Error with the Optical Media Advance Sensor (OMAS) component or with the cable between sensor and
the PCA.
Corrective Action:
Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
Check that the Printer has the latest firmware version, if not, update the firmware to the latest version.
Check that the OMAS Module cable is not damaged and is correctly connected to the OMAS
Controller PCA.
Replace the OMAS Controller Card Page 437
Replace the OMAS Module Page 424.
SE Code: 50.01:11 - Error with Media Advance Sensor or with cable
Problem Description:
Error with the CAN cable of the CAN driver.
Corrective Action:
Check the cable is not damaged and is correctly connected between the Sausalito and the OMAS
Controller Board.
Replace the OMAS controller PCA