106 Chapter 3 System Error Codes
System Error Codes
Replace the Sausalito PCA Page 444
Replace the cable between the Sausalito and the OMAS Controller Board.
SE Code: 50:11 - Media navigation problem
Problem Description:
Navigation problems, caused by a mis-positioned sensor, DOF or skew issue.
Corrective Action:
Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
Check that the Printer has the latest Firmware version, if not, update the firmware to the latest
version.
Check that the OMAS Module cable is not damaged and is correctly connected to the OMAS
Controller PCA.
Replace the OMAS Controller Card Page 437
Replace the OMAS Module Page 424
SE Code: 50:14 - Firmware version mis-match
Problem Description:
FW version mismatch between the controller fw and the version of the file in the Engine disk.
Corrective Action:
Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
Check that the Printer has the latest Firmware version, if not, update the firmware to the latest
version.
Replace the OMAS Controller Card Page 437
SE Code: 50.02:10 - Problem with OMAS Controller PCA
Problem Description:
Error with the media advance sensor controller board.
Corrective Action:
Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
Check that the Printer has the latest Firmware version, if not, update the firmware to the latest
version.
Check that the CAN cable and the Encoder Cable are correctly connected to the OMAS PCA and
the Sausalito PCA.
Check the connection between the OMAS PCA and the Sausalito PCA (the Sausalito is the card
connected just behind the OMAS PCA).
Check that the OMAS Module cable is not damaged and is correctly connected to the OMAS
Controller PCA.
Replace the OMAS Controller Card Page 437.