Continuable and Non-Continuable Error Codes 107
System Error Codes
SE Code: 51:10 - An error has been detected with the Window Lock Sensor
Problem Description:
Error detected with the sensor on the Window.
Corrective Action:
Check that the Window Sensor cable is not damaged and is correctly connected to the Interconnect
PCA.
Check the Window sensor locks are activating the Window Lock Sensor.
Replace the Left and Right Window Lock Sensor page 345 & page 347.
SE Code: 51.01:10 - Problem with the Service Station door sensor
Problem Description:
Error detected with the sensor on the Service Station Door.
Corrective Action:
Check that the Printhead Maintenance Cartridge Door Sensor
cable is not damaged and is correctly
connected to the Interconnect PCA
.
Perform the Sensors service test Page 173.
Replace the Printhead Maintenance Cartridge Door Sensor Page 554.
SE Code: 52:01 - A problem with the Drop Detector
Problem Description:
Drop Detector fiber detected.
Corrective Action:
Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
Check that the Ink Funnel is correctly installed. Use the ‘Replace Ink Funnel’ process to access the
funnel.
Check that there is no obstructions in the funnel, such as media which would block the detector
signal.
Replace the Drop Detector Page 377.
SE Code: 52:10 - A problem with the On/Off switch in the Drop Detector
Problem Description:
Drop Detector switch On/Off failure.
Corrective Action:
Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the
power cord and power On the Printer.
Check that the
Drop Detector cable is not damaged and is correctly connected to the Service Station
cable
.
Check that the
Service Station cable is not damaged and is correctly connected to the Interconnect
PCA
.