172 Chapter 4 Service Tests, Utilities & Calibrations
Tests, Utilities & Calibrations
3. The following message is displayed on the front panel, use the up and down arrows to change the
resistor value to match with the resistor value of the ‘Burst’ resistor. This value is also provided with
the part from the factory. Press enter when finished.
4. Confirm that the values have been correctly entered and press the OK key.
5. Press enter to finish and shut down the printer.
The resistor values will come with the service part from the factory. If for any reason they are not
available, measure the values from the Power Control PCA 5 pin connector with a mulitimeter.
In the table shown below are the limits of the resistor values, these can also be used if the values are
not available with the part.