356 Chapter 8 Removal & Installation
Removal & Installation
7. Remove four T-10 screws that secure the Primer
Assembly to the Service Station.
8. Remove the Primer Assembly from the Service Station.
Installation of the Primer Assembly
1. When installing the new Primer Assembly, it is
important to note that the internal tube (red) is shorter
than the external tube (green).
2. Reset “4.7.7. Primer Cycles”
⇒
See page 201.
3. Perform the Calibration “5.6.2 Primer Calibration”
⇒
See page 220.
NOTE: Use a short screw driver, less than
10 cm in length.
NOTE: When installing the Primer Assembly,
use the identification marks on the Primer
Assembly Tubes to ensure they are correctly
connected.