152 Chapter 5 Service Calibrations
Service Calibrations
Service Calibrations
The Printer has several calibration procedures that must be performed under certain conditions.
The following is a list of all internal service calibrations available in the Printers. See page 153
for
instructions on how to enter the service calibrations menu.
1. Scan Axis Calibration See page 154
The purpose of this Service Calibration is to carry out a PWM check, and calibrate the intensity of
the Line Sensor.
2. Paper Advance Calibration See page 157
The purpose of this Service Calibration is to calibrate the nominal advance of the media. This cali-
bration is necessary to control the exact movement of the media in order to avoid print quality prob-
lems like banding.
3. Drop Detector Calibration See page 162
The purpose of this Service Calibration is to calibrate the Drop Detector (located in the Service Sta-
tion) in relation to the Carriage Assembly.
4. Line Sensor Calibration See page 163
The purpose of this Service Calibration is to calibrate the intensity of the Line Sensor. An incorrect
calibration can result in edge-detection failures during media loading and incorrect reading of prints
that are used for alignment or calibration.
5. Vacuum Calibration See page 166
The purpose of this Service Calibration is to set the default nominal and real values of the Vacuum
Fan.
6. OMAS Calibration See page 167
The purpose of this Service Calibration is to calibrate the Optical Media Advance Sensor.
7. Primer Calibration See page 173
8. The purpose of this Service Calibration is to calibrate the Primer.
9. Platen Blue Line Calibration See page 177
The purpose of this Service Calibration is to calibrate the blue line which is marked on the Print
Platen.
NOTE: REMEMBER THAT CERTAIN CALIBRATIONS ARE REQUIRED EVEN IF AN ASSEMBLY
HAS BEEN DISASSEMBLED TO GAIN ACCESS TO ANOTHER ASSEMBLY OR COMPONENT.
NOTE: If ALL the Calibrations need to be performed (for example, when both the HDD and
the ISS PCA have been replaced), you must perform them in the following order:
Vacuum Calibration.
Drop Detector/Service Station Calibration.
Line Sensor/Scan Axis Calibration.
Paper Advance Calibration.
Platen Blue Line Calibration.