306 Chapter 8 Removal & Installation
Removal & Installation
13 . Lower then lift the Vacuum Fan out of its attachment.
14 . Remove the Vacuum Fan from the Printer.
NOTE: When connecting the Vacuum Fan
cables to the Interconnect PCA, make sure you
connect the cable with the label marked
Vacuum Fan 1 to connector 1 and the cable
with the label marked Vacuum Fan 2 to
connector 2. You can verify if both cables are
labelled correctly by the actual markings on the
Vacuum Fan.
NOTE: Make sure that the OMAS ribbon
cable is free of slack when you install the cable
clamp.
NOTE: After installing the NEW Vacuum Fan,
make sure you perform the following Service
Calibration:
• Paper Advance Calibration
⇒
Chapter 5.